To configure and test a device on the Softruck platform, it must first be correctly registered in the tool. If this has not yet been done, you can check our tutorial: How to register a chip and device.
In this manual, we will learn how to perform this configuration via text messages (SMS), which must be sent to the number of the chip embedded in the respective equipment.
Before you start sending the configuration commands:
Install the SIM chip in your device.
Connect the equipment to a 12V power source.
Make sure the device is in an open area to facilitate communication.
Once this is done, send the basic configuration messages to your tracker:
1. Command to configure APN:
802#APN#USER#PASSWORD#
Note: It is important to note that the APN, user, and password information must be changed with the correct information, as they vary according to the chip supplier and the operator used.
2. Configure IP and Port:
803#IP#PORT#
3. Configure communication time:
730#TIME#
INTERVAL FROM (10 to 60 SECONDS)
4. Command to configure default time with the vehicle stopped
SUP#TIME#
INTERVAL OF (1 to 60 MINUTES)
FACTORY DEFAULT 5 MINUTES.
That's it! Just check the status of the device in the Softruck tool. If the equipment does not communicate, check the chip, the registered IMEI, and the settings sent.
Additional commands:
Command to lock vehicle
222#
Command to unlock vehicle
333#
Command to set time zone
801#TIMEZONE#
EX: 801#E8#
Command to view vehicle location
666#
If you have reached this point in our article, we believe you may be interested in talking to our team of experts. Click the button below to learn more:



