Before starting to send the configuration commands:

  • Install the SIM chip in your device.

  • Connect the equipment to a 12V power source.

  • Make sure the device is in an open area to facilitate communication.

Once this is done, send the following commands to configure your E3+ device.

E3+ configuration commands:

Command to start the settings:

REG000000#

Command to activate SMS response:

SMS1

TCP mode command:

TCP

Command to configure APN:

APN*apn*user*password

Note: It is important to note that the APN, user, and password information must be changed with the correct information, as they vary according to the chip supplier and the operator used.

IP and port configuration command:

IP1#18.232.201.231#3682#

DNS command:

If the device does not communicate with the IP/port, the DNS can be set to enable this communication.

DNS#e3.softruck.com#3682#

Command to configure Ignition On reporting time:

HB30


Command to configure Ignition Off reporting time:

SHB600

Command to configure Timezone:

TZW0

Command to turn off SMS response:

SMS0

That's it! Just check the status of the device online using the Softruck tool. If the device does not communicate, check the chip, the registered IMEI, and the settings sent.

Additional Commands:

Commands to restart the device:

REG000000#
SMS1
EN
RESTART

Command to request location:

REG000000#
SMS1
CQ
LOCA

Enable Chinese or English version:

Chinese: CN
English: EN

Communication time:

TX600

Restart Module:

English version: RESTART
Chinese version: CQ

Lock:

English version: ENGOFF
Chinese version: DD

Unlock:

English version: ENGON
 Chinese version: TD

Communication time with ignition ON (60 seconds):

HB60

Communication Time with Ignition OFF (1 hour):

SHB3600

Request Position (SMS):

English version: LOCA or GOOGLE
Chinese version: DW or GOOGLE

Reset Factory Settings:

English version: RST
Chinese version: CSH

Request IMEI:

IMEI

Request ICCID:

ICCID